The radiators are warm, the boiler is on, but the shower runs cold and the kitchen tap never heats up. Having no hot water while the heating works is one of the most common calls in winter, and it is confusing, because the boiler is clearly doing something. The good news is that the cause is often simple, and a few checks will tell you whether it is something you can sort yourself or a job for an engineer.
First, which system do you have?
The checks depend on how your home makes hot water.
A combi boiler heats water on demand. There is no hot water tank, and the boiler fires up when you turn on a hot tap. Most London flats have one.
A system or regular boiler with a cylinder heats water in advance and stores it in a tank, often in an airing cupboard. Many older houses use this setup.
No hot water with a combi boiler
Check the hot water setting
Many combi boilers have separate controls for heating and hot water. It is surprisingly common for the hot water dial to have been turned down or switched off, by a cleaner, a child or a curious guest. Turn it up and run a hot tap for a minute.
Check the pressure
Look at the pressure gauge on the front of the boiler. It should usually sit around 1 to 1.5 bar when the system is cold. If it has dropped close to zero, the boiler may still run the heating weakly but struggle with hot water, or lock out altogether. Your boiler manual will show how to top up the pressure using the filling loop. If it keeps dropping, there is a leak somewhere, and that needs a professional.
Look for an error code
Most modern boilers show a code or a flashing light when something is wrong. Write it down. Often the manual explains it, and a reset is all that is needed. If the same code returns after a reset, do not keep resetting it.
Check for a frozen condensate pipe
In cold snaps, the small plastic pipe that runs from the boiler to an outside drain can freeze. The boiler then shuts down. If it is freezing outside and the boiler shows a fault, pour warm (not boiling) water along the outside section of the pipe, then reset the boiler.
Is the diverter valve stuck?
Inside a combi boiler, a diverter valve switches between heating and hot water. When it sticks, the heating keeps working and the hot water stops. This is one of the most likely causes when the radiators are warm but the taps stay cold. It is not a DIY repair. It needs a qualified engineer.
No hot water with a hot water cylinder
Check the timer and programmer
Systems with a cylinder usually have a programmer with separate heating and hot water schedules. A power cut, the clocks changing or a missed button can leave the hot water switched off. Set it to constant or boost for an hour and see if the water heats up.
Check the cylinder thermostat
Most cylinders have a small thermostat strapped to the side, usually set to around 60 degrees. If it has been turned down, the water will stay lukewarm.
Try the immersion heater
Many cylinders also have an electric immersion heater as a backup. Switching it on will give you hot water while you work out what is wrong with the boiler side. If the immersion works, the cylinder itself is fine.
A faulty motorised valve
Like the diverter valve in a combi, a motorised valve sends hot water from the boiler to either the radiators or the cylinder. If it fails, the heating can work while the cylinder stays cold. Again, this is an engineer’s job.
When you have no hot water and need help fast
Call for help straight away if you smell gas, if water is leaking from the boiler, or if the pressure keeps dropping after you top it up. Any work inside a gas boiler must be done by a registered gas engineer. Never take the casing off yourself.
For everything else, it helps to have the boiler make and model, any error code and a note of what you have already checked. That makes the visit quicker and the fix more likely first time.
Keeping hot water problems away
- have the boiler serviced once a year, ideally before winter
- check the pressure gauge every few weeks
- keep the condensate pipe insulated if it runs outside
- bleed radiators so the system is not full of air
- do not ignore small leaks or dripping valves
Getting it fixed in London
For hot water repair in London, CityPrime’s plumbing and heating team deals with hot water faults, low pressure, leaks and valve replacements across London. If you are left with no hot water in the middle of winter, or water is coming from the boiler, the emergency call-out service can send someone quickly. For landlords, a fast fix also keeps tenants comfortable and avoids bigger problems later.
Hot water questions
Why do I have no hot water but the heating works?
In a combi boiler, the most common cause is a stuck diverter valve, low pressure or the hot water setting being turned down. With a cylinder, it is often the programmer, the cylinder thermostat or a faulty motorised valve.
How do I reset my boiler?
Most boilers have a reset button or a reset position on a dial. Check the manual for your model. If the boiler locks out again after a reset, stop and call an engineer rather than resetting it repeatedly.
What pressure should my boiler be?
Usually around 1 to 1.5 bar when the system is cold. If it drops close to zero, top it up using the filling loop as the manual explains. If it keeps dropping, there is likely a leak.
Can a frozen pipe stop my hot water?
Yes. A frozen condensate pipe on a combi boiler makes the boiler shut down. Pour warm, not boiling, water along the outside section of the pipe, then reset the boiler.
Is no hot water an emergency?
It is urgent if you smell gas, water is leaking from the boiler or the pressure keeps dropping. Otherwise, run the basic checks first and book an engineer if the hot water does not come back.